2021 Covidien BIS LOC 4-Channel Module 185-1016-AMS w/ IF Cable (Parts) ~ 39131

Condition: For parts or not working
Notes: When tested with a Covidien BIS Complete Monitor, the module failed to initialize, displaying error code “BISx initialization error 502 [1502],” and is therefore offered for parts or repair only.
Brand: Covidien 
Model: 185-1016-AMS
Made In: USA

More details


$116.00

39131

Availability: This product is no longer in stock.

Product details

Manufacturer

Covidien / Medtronic

Item:

2021 Covidien BIS LOC 4-Channel Module 185-1016-AMS w/ Interface Cable 10115253 – Parts

Model/Cat #        

185-1016-AMS

Serial No.        

B447914

Made In:             

USA

Date of Manufacture:  

2021


Short Description:

Medtronic / Covidien BIS LOC 4-Channel module designed for BIS anesthesia depth monitoring systems. Unit includes module-to-monitor interface cable (P/N 10115253). The module shows normal cosmetic wear and failed initialization during testing.

Module Interface Cable:

  • Part Number: 10115253
  • Cable Serial Number: 713-564-3021
  • Approximate Length: ~10 ft

 

Condition Summary:

Overall Condition
Good cosmetic condition with signs of normal prior clinical use.
Housing
Module housing shows light scuffs and surface scratches consistent with routine handling. No cracks or structural damage observed.
Rear Mounting Clamp
Posterior mounting clamp is intact and in good condition.
Connectors
Multipin connectors appear clean and intact with no visible bent pins or corrosion.
Cable Condition
Interface cable (~10 ft) is in good overall physical condition. A slight insulation tear is noted at the strain relief where the cable meets the connector end. No exposed internal wiring is visible and the remainder of the cable jacket appears intact.
Patient Interface Port
Patient interface connector is clean and appears structurally intact.


Functionality Summary:

The module was connected to a Covidien BIS Complete Monitor (REF 185-0151) using the included interface cable.
During initialization the monitor displayed the following error message:
“BISx initialization error 502 [1502]
Reconnect BISx and try again.”
The module failed to initialize, preventing the BIS system from entering operational mode.
Based on this result, the device is being offered for parts or repair.

What's Included:
• Covidien / Medtronic BIS LOC 4-Channel Module (REF 185-1016-AMS)
• Module Interface Cable (P/N 10115253)

What's Not Included:

• BIS monitor / testing monitor
• Patient interface cable (PIC)
• BIS sensors / electrodes
• User manual
• Any accessories not shown in photos

Buyer Advisory Note:
This module failed initialization during testing and is being sold for parts or repair. Buyers should assume that service or internal component repair may be required before clinical use.
Shipping Note:
The module and cable will be securely packaged to protect connectors during shipment.

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*

 

Stock ID : 39131 (P.O 2022) (WH104 SC4) 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: PARTS ONLY, please refer to images for cosmetic condition.

  1. 1.    Overall Condition: As seen in images - AS IS
  2. 2.    Physical Condition: Please review images before bidding - Good
  3. 3.    Working Condition: The module failed to initialize, preventing the BIS system from entering operational mode. Based on this result, the device is being offered for parts or repair.....Will receive item as pictured ……………(Offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)