Invivo MDE Escort M10 Patie...
Invivo MDE Escort M10 Patient Monitor (Model 20415) W/ NEW Accessories ~ 38849
Item specifics
- Used
- Model
- 20415
MPN- Escort M10
Product details
Manufacturer | Invivo / MDE |
Item: | Invivo MDE Escort M10 Patient Monitor – Model 20415 | NIBP ECG RESP Masimo SpO2 IBP TEMP Printer W/ New Accessories |
Model/Cat # | Escort M10 | 20415 |
Serial No. | F1988 |
Made In: | USA |
Date of Manufacture: | U/K |
Voltage: 100–240V ~ 50/60 Hz, 2.8A
Short description:
Fully featured Invivo Escort M10 multiparameter patient monitor with installed NIBP, ECG/RESP, Masimo SpO₂, IBP1 & IBP2, TEMP1, and integrated printer. Includes new compatible patient accessories (SpO₂ sensor, 5-lead ECG cable, Temp probe, NIBP cuff & hose, and power cord). Monitor powers on, passes self-test, LCD bright and clean, reaches patient monitoring screen, and function keys and trim knob work properly.
Installed Module:
- Escort Link Radio Interface Module
- Model: 2001V
- Serial No.: F2112
- Note: RF antenna missing
- Monitor powers on and completes system diagnostics successfully
- LCD bright, clear, and scratch-free
- No cracks or structural damage noted; light cosmetic scuffs from prior use
- Control panel buttons, trim knob, front soft keys all responsive
- Foot stands intact
- Date/time clock battery appears weak (defaulted to 01/01/2000) – time/date can be reset
- Printer installed (printer paper NOT included)
- Escort Link RF module installed but antenna missing
- Powers ON → Passes Self-Test → Loads to Monitoring Screen
- Parameters recognized and display properly
- Alarm LED indicator works
- Menus, alarm setup access, and patient type profiles functional (Adult / Pediatric / Neonatal selectable)
- No further long-term functional / clinical calibration testing performed
- ✔ Invivo Escort M10 Monitor (Model 20415)
- ✔ Escort Link Radio Interface Module (Model 2001V – antenna missing)
- ✔ New Compatible SpO₂ Sensor – Reusable – Ref: SP9315L – Masimo Compatible
- ✔ New 5-Lead ECG Cable – Ref: G5140S
- ✔ New Reusable Temperature Probe – Skin Type – Ref: ST1307
- ✔ New Adult Reusable NIBP Double Tube Cuff (25–35 cm) – Ref: SC1721-3636
- ✔ OEM NIBP Double-Tube Adapter Hose – approx. 15 ft – Excellent Used Condition
- ✔ Power Cord – IEC 3-Prong
- ✖ RF antenna for escort module
- ✖ Printer paper
- ✖ Rolling stand
- ✖ User manual
- ✖ Any disposable / consumable items not listed
- ✖ IBP transducers / IBP cables
- “DANGER: Explosion hazard. Do not use it in the presence of flammable anesthetics.”
- “WARNING: Do not remove or install module while monitor power is ON. Switch monitor OFF first and disconnect AC power cord from monitor.”
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38849 (P.O 1200) (R1 C7)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: Has been tested at our end & is in good functionality as shown in the images....will receive item as pictured ……………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)