2011 GE Dash 4000 Patient M...
2011 GE Dash 4000 Patient Monitor ONLY~ 38288
Item specifics
- Used
Product details
Manufacturer | GE Medical Systems |
Item: | 2011 GE Dash 4000 Patient Monitor ONLY (ECG / SpO₂ / NIBP / IBP / Temp / CO2) |
Model/Cat # | Dash 4000 / Ref 2035598-202 |
Serial No. | SHQ114334895A |
Made In: | USA |
Date of Manufacture: | 2011-10 |
Voltage: 100–240 V AC • 50/60 Hz • 75 W
Short description:
GE Dash 4000 multi-parameter patient monitor with Masimo SpO₂, NIBP, ECG, ART1/IBP, Respiration, and Temperature. The unit boots properly, loads all menus, recognizes installed hardware, and displays parameters normally. CO₂ hardware is present, but the CO₂ software license is not active. Monitor is being sold as-is because a “Preventive Maintenance Required” message appears on screen.
No accessories or batteries included.
CE Mark: CE 0459
NBP Technology: DINAMAP® SuperSTAT
SpO₂ Technology: Masimo
Software Configuration:
- Admit Menu Type: Combo
- Patient Type: Adult – ICU
- Enabled Software Options (from configuration screen): 1 BP 12SL ECG ACI-TIPI Network Cardiac Atrial Fib ECG Intellitrate
- Not Enabled: CO₂ software, Additional waveform packages, Printer features
- ECG SpO₂ – Masimo type NIBP Respiration Temperature (T1) ART1 (Invasive Blood Pressure #1)
- Second IBP channel hardware present CO₂ hardware installed (module cavity + connectors)
- → CO₂ software NOT enabled
- ECG – ON ART1 – ON SpO₂ – ON NIBP – ON RR – ON TP1 – ON ALRM – OFF
- CO₂ – NOT active in software
- Front bezel: good overall condition
- Screen/LCD: bright, clear, responsive
- Buttons & trim knob: functional
- Back housing: small stress crack visible (see images)
- Bottom base/desk stand: left-front foot is chipped, but structure remains intact
- Moderate surface scuffs from normal clinical use
- Ports and connectors clean and intact
Operational Condition:
- Monitor powers on and boots correctly
- All tested parameters (ECG, SpO₂, NIBP, Temp, ART1, RR) function using external accessories
- No freezing or unexpected restarts
- CO₂ hardware recognized, but software NOT enabled
- Device passes self-test except for: “PREVENTIVE MAINTENANCE REQUIRED” → Hence listed in this condition
Battery Status:
- Battery A: No battery installed
- Battery B: No battery installed
- Charging bays functional but empty
- Powers on reliably
- Main menus accessible
- Waveforms display normally
- NIBP, SpO₂, ECG, RR, and ART1 readings tested with accessories
- Networking port present
- No printer installed
- Suitable for parts, refurbishment, or use by a qualified biomedical technician
- Sold AS-IS due to PM requirement message
- ✓ GE Dash 4000 Patient Monitor (SN: SHQ114334895A)
- ✓ AC Power Cord
- ✗ Batteries
- ✗ SpO₂ sensor
- ✗ NIBP hose/cuff
- ✗ ECG cable/leads
- ✗ Temperature probe
- ✗ IBP transducers
- ✗ CO₂ sensor/lines
- ✗ Printer module
- ✗ Mounts, stands, accessories, or any items not listed as included
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38288 (P.O 4018) (WH104 SCC15)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images : AS-IS
- 2. Physical Condition: Please review images before bidding : Good
- 3. Working Condition: Has been tested at our end | PM Required......Will receive item as pictured…………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.