Datascope Passport 2 (Masim...
Datascope Passport 2 (Masimo SpO2 ECG NBP T/Print) Colored Monitor & Leads~37183
Item specifics
- Used
- Model
- Passport 2
MPN- 0998-00-0900-5014A
Product details
Manufacturer | DATASCOPE CORP |
Item: | Datascope 0998-00-0900-5014A Passport 2 Coloured Patient Monitor W/ Leads |
Model/Cat # | Passport 2 / 0998-00-0900-5014A |
Serial No. | TS15976319 |
Made In: | USA |
Date of Manufacture: | U/K |
Voltage: 100-240V 50-60Hz 0.6-0.3A
Short Description:
For sale is a Datascope Passport 2 Colored Patient Monitor (P/N: 0998-00-0900-5014A), tested at our facility and confirmed to be in good functional condition. Includes a complete set of new patient accessories and power cord. Please refer to the images for actual condition and included items.
Device Overview:
Software Version: 0996-00-0045-001
Battery Status: Installed; condition unknown
Display: Polychrome, non-touch LCD; may have light surface scratches
Printer: Installed and functional, paper included
Date/Time: Date is correct; however, clock battery is dead, so date/time must be reset after each shutdown
Monitored Parameters:
Temperature
NBP
SpO₂ (Masimo)
ECG
Physical Condition:
Signs of moderate use
No dents or cracks observed
Surface scratches and scuffs may be present
Trim knob, softpad, and handle all intact and functional
Included Accessories (All New):
SpO₂ Reusable Sensor (Masimo) – Ref: SP9315
ECG Cable with Leads – Ref: SG5140S
NBP Hose – Ref: SH1010S
Adult Cuff – Ref: SC1711-06 (25–35 cm)
Temperature Probe – Ref: ST1307 (Skin type)
Additional Details:
Power Cord: Included
Stand Mount: Included
User Manual: Not included
Package Includes:
Datascope Passport 2 Monitor (P/N: 0998-00-0900-5014A)
SpO₂ Sensor (Masimo – Ref: SP9315)
ECG Cable with Leads (Ref: SG5140S)
NBP Hose with Adult Cuff (SH1010S / SC1711-06)
Temperature Probe (Ref: ST1307)
Power Cord
Only the items shown in the photos are included. If it is not pictured, it is not part of the sale.
This is a non-sterile device, cleaned at our facility.
Shipping Weight: 20 lbs
Stock ID : 37183 (P.O 2014) (WH104 CC11)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Good
- 2. Physical Condition: Please review images before bidding : Fair
- 3. Working Condition: Has been tested at our end & is in good functionality...will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)