For orders, please call: 1-952-953-0653

$0Checkout 0 Item(s)

MENU

    

Diasonics 7.0 MI 2D P/N 100...

Diasonics 7.0 MI 2D P/N 100-02876-00 Linear Array Probe (Gatway & Synergy) /8810

Item specifics

Condition:Used : 
Seller Notes:Enjoys good cosmetics, Removed in working condition
Brand:

Diasonics

MPN:

P/N 100-02876-00

Model:

7.0 MI 2D

Country/Region of Manufacture:Korea, Republic of

More details


$195.88

8810

Availability: Item Available

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer :

 

Diasonics Ultrasound Systems 

Item:

 

Diasonics 7.0 MI 2D P/N 100-02876-00 Linear Array Probe for Gatway & Synergy  Series 

Model/Cat #

 

100-02876-00  

Serial No.

 

1159

Made In:

 

USA 

Date of manufacture

 

NA

 

Voltage                        

Short description……………….

  1. 1.     Sale is for imaged item only
  2. 2.     Applications : General vascular use

         

  1. 3.      Systems :  compatible with the  Gatway & Synergy  series ultrasound systems

 

Note: Please note that provided info are for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy


  1. 4.      Specifications :
  2. Transducer analysis :
  • Linear array ultrasound transducer
  • General vascular use
  • Frequency: 7.0 MHz

System connector: No foreign objects , crack or dent or bents , some scratches 


Strain relief and cable : Has discoloration of the cable BUT has no crack, cuts, tears, abrasion, kinking or crushing 


Head & Handle: may has scratches 


Acoustic lens or cap: No cuts , no gouging, abrasion, de-lamination or discoloration. 


Scan Analysis :

Was tested and passed dated 2/25/05

  1. Sterilize : No
  2. Manual : No
  3. Cleaned : Yes
  4. Case : No 
  5. Shipping Weight: 7 lbs.
  6. Stocks ID:  8810

Location : R2C5

 

 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition:

  1. 12.             Overall Condition:- As seen in images  - Very Good 
  2. 13.  Physical Condition:  Please review images before bidding –  Good 
  3. 14.  Working Condition:  Unit was last tested and passed assessment dated 2-25-2005........We do not comment on the functionality of used probes, ................Enjoys 14 days hassel free return  ..........will receive item as pictured ……………(offered AS IS)
  4. 15.             “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 16.             Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  6. 17.             Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

 Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Added Comments:

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.

text/x-generic footer.tpl ( UTF-8 Unicode text )