For orders, please call: 1-952-953-0653

$0Checkout 0 Item(s)

MENU

    

Siemens Antares VF13-5 P/N ...

Siemens Antares VF13-5 P/N 04838848 Linear Array Ultrasound Transducer ~15394

Item specifics

Condition:Used : 
Notes:See images for cosmetics Review Air Phantom and Vascular Scans, HAS FEW WEAK ELEMENTS
Model:

VF13-5

MPN:

04838848

Country/Region of Manufacture:JapanBrand:

Siemens

More details


$396.00

15394

Availability: This product is no longer in stock.

Product details

Manufacturer :

 

Siemens Ultrasound Systems 

Item:

 

Siemens Antares VF13-5 P/N 04838848 Linear Array Transducer  

Model/Cat #

 VF13-5 P/N 04838848 

VF13-5 P/N 04838848 

Serial No.

 

F13C062916

Made In:

 

China  

Date of manufacture

 

2006

 

Voltage                        

Short description……………….

  1. 1.     Sale is for imaged item only
  2. 2.     Applications :  Breast , Superficial vascular, Small parts, Musculoskeletal, Orthopedic, Cerebrovascular, MSK, Orthopedics
  3. 3.      Systems :  Siemens Antares

Note: Please note that provided info are for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy

  1. 4.      Specifications :
  2. Transducer analysis :
  • Frequency Bandwidth: 13 – 5 MHz

System connector: No foreign objects , crack or dent some scratches , No BENT PIN


Strain relief and cable :  has no crack, cuts, tears, abrasion, kinking or crushing 


Head & Handle: may has scratches , chipped at one corner (Image # 10)


Acoustic lens or cap: : lens looks smooth


Scan Analysis :

Review Air scan Image # 1,2 , Phantom Scan Image # 3 & Vascular Scan Image # 4, 5, 6............Has weak elements 

  1. Sterilize : No
  2. Manual : No
  3. Cleaned : Yes
  4. Case : No
  5. Shipping Weight: 7 lbs.
  6. Stocks ID:  15393 / WHC4
 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition:

  1. 12.             Overall Condition:- As seen in images  - Good
  2. 13.  Physical Condition:  Please review images before bidding –  Fair 
  3. 14.  Working Condition: Review Air scan Image # 1,2 Phantom Scan Image # 3 & Vascular Scan Image # 4, 5, 6..........Has weak elements ..... We do not comment on the functionality of used probes.......Exercise your judgment after reviewing the images .................Enjoys 30 days hassel free return  ..........will receive item as pictured ……………(offered AS IS)
  4. 15.             “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 16.             Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  6. 17.             Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

 Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.