For orders, please call: 1-952-953-0653

$0Checkout 0 Item(s)

MENU

    

2003 Acuson 3V2c Wideband ...

2003 Acuson 3V2c Wideband Phased Array Transducer For Acuson Sequoia~13000

Item specifics

Condition:For parts or not working : 
Notes:May has cosmetic blemishes Review Images for cosmetics , see images for functionality (REVIEW AIR SCAN , PHANTOM SCAN and VASCULAR SCAN)............color doppler is patchy
Brand:

Siemens

MPN:

08260628

Model:

3V2c

Country/Region of Manufacture:Mexico

More details

On sale On sale!
$76.00

13000

Availability: This product is no longer in stock.

Product details

Manufacturer :

 

Siemens Ultrasound Systems 

Item:

 

Acuson 3V2c Wideband Phased Array Ultrasound Transducer for Acuson Sequoia

Model/Cat #

 

08260628 / 3v2c

Serial No.

 

30920208

Made In:

 

Mexico 

Date of manufacture

 

2003

 

Voltage                        NA

Short description………………. SALE IS FOR PROBE ONLY 

  1. 1.     Sale is for imaged item only
  2. 2.     Applications : Caridac / TCD

         

  1. 3.      Systems :  compatible with the Acuson Sequoia series ultrasound systems

 

Note: Please note that provided info are for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy


  1. 4.      Specifications :
  2. Transducer analysis :
  • 5-7 mghz
  • Transcranial Imaging Capabilities
  • 2D Imaging
  • Spectral Doppler audio performance

System connector: No foreign objects , crack or dent or bents , some scratches 

MAY HAS PATINA

Strain relief and cable : Starin relief looks good 

 Cable may has discoloration, no cuts or tears 

Head & Handle: may has scratches ,  


Acoustic lens or cap: looks smooth  


Scan Analysis :

See monitor images and make up your mind 

Color flow is patchy / may has weak elements / Review air scan, phantom scan and vascular scan to make up your mind !

  1. Sterilize : No
  2. Manual : No
  3. Cleaned : Yes
  4. Case : No
  5. Shipping Weight: 7 lbs.
  6. Stocks ID:  13000 / R1C4
 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition:

  1. 12.             Overall Condition:- As seen in images  -Fair 
  2. 13.  Physical Condition:  Please review images before bidding –  Good 
  3. 14.  Working Condition:  See monitor images and make up your mind 

Color flow looks patchy / may has weak elements / Review air scan, phantom scan and vascular scan to make up your mind !!.....We do not comment on the functionality of used probes, please review images and take a decision ................…………(offered AS IS)

  1. 15.             “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  2. 16.             Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  3. 17.             Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

 Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.


text/x-generic footer.tpl ( UTF-8 Unicode text )