ZONARE E9-4 Endocavity Ultrasound Transducer Probe ~ 40303

Item specifics

Condition
For parts or not working
Seller Notes
“Pre-owned ZONARE E9-4 Endocavity Ultrasound Probe in good cosmetic condition. Tested with a compatible ZONARE system; probe initializes and produces images, but persistent image artifacts were observed during air and phantom scans."
Model
E9-4

More details


$455.20

40303

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

ZONARE E9-4 Endocavity Ultrasound Transducer Probe – Image Artifact

Condition: Pre-Owned | Good Cosmetic Condition | Tested – Image Artifact Present | Repair Recommended


Device / Instrument Profile

Manufacturer / Identification

  • Manufacturer: ZONARE Medical Systems, Inc.

  • Model: E9-4  Device Type: Endocavity Ultrasound Transducer

  • Frequency Range: 4–9 MHz   Part Number (P/N): 84002

  • Serial Number (S/N): 01128EX106B  CE Marking: CE 0086

  • Probe Type: Endocavitary / Intracavitary

  • Connector: Proprietary High-Density Multi-Contact Array Connector with Mechanical Lock

  • Cable Length: Approximately 7 feet Manufactured in: USA


Short Description

The ZONARE E9-4 is an endocavity ultrasound transducer designed for compatible ZONARE ultrasound systems, primarily for gynecological and endovaginal imaging applications.

The probe was connected to a compatible ZONARE ultrasound system for basic functional testing. Imaging was successfully initiated; however, persistent image artifacts were observed during testing.


Condition Summary

  • Overall good cosmetic condition with normal signs of previous use.

  • Probe head and handle appear intact, without visible cracks, dents, or significant damage.

  • Acoustic lens appears intact, without visible cuts, tears, or surface deterioration.

  • Approximately 7-foot cable is free of visible cuts, tears, or exposed wiring.

  • Cable strain reliefs appear intact at both ends.

  • High-density multi-contact connector arrays appear intact, without obvious bent or damaged contacts.

  • Connector locking mechanism is present and intact.


Functionality / Testing

Testing Status: Tested – Image Artifact Present

  • System Compatibility: Connected to a compatible ZONARE ultrasound system (not included).

  • Initialization: Probe successfully recognized and initialized; imaging presets loaded.

  • Air Scan: Image imperfections/artifacts observed.

  • Phantom Scan: Similar image imperfections persisted during phantom testing.

  • Body Scan: Basic right upper quadrant (RUQ) scanning performed, with liver and kidney images obtained for demonstration purposes only.

  • Image Quality: Ultrasound images were generated; however, persistent artifacts may indicate early transducer element degradation or another imaging-related defect.

  • Testing Limitations: No comprehensive diagnostic testing, individual element evaluation, or formal technical assessment was performed. No formal test report is available.

The probe produces ultrasound images but exhibits persistent image artifacts. Further technical evaluation and possible repair are recommended. Full diagnostic performance is not verified.


Included

  • ZONARE E9-4 Endocavity Ultrasound Transducer with Attached Cable and Connector

Not Included

  • ZONARE Ultrasound System (used for testing only)

  • Probe Storage or Carrying Case

  • Additional Accessories

  • Consumables or Disposables

  • User Manual


Buyer Advisory

This transducer has undergone basic imaging tests only. Persistent image artifacts were observed during air and phantom testing. The probe is offered with this disclosed limitation and may require professional evaluation or repair before diagnostic use.

The actual transducer pictured is the unit supplied. Sale is for the imaged items only.


Stock ID: 40303 (P.O 1200) (WH104 SCB2)


Purchase Terms & Buyer Protections

Condition & Use Notice

Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.