GE C721 P/N 2121267-2 Conve...
GE C721 P/N 2121267-2 Convex Array Transducer for GE Logiq 400 & 500 (11914)
See images for cosmetics, TAKE A LOOK ON MONITOR IMAGES FOR FUNCTIONALITY , Reviw Air scan (Image # 1 and 2 ) Phantom Scan (Image # 3) and Solid Organ scans (Image # 4) ......has dead crystals and weak elements
Product details
Manufacturer : | GE Medical corp | |
Item: | GE C721 P/N 2121267-2 Convex Array Transducer for GE Logiq 400 & 500 systems | |
Model/Cat # |
| C721 P/N 2121267-2 |
Serial No. |
| 365806YM9 |
Made In: | Japan | |
Date of manufacture |
| 8/1997 |
Voltage : NA
Short description……………….
- 1. Sale is for imaged item only
- 2. Applications : abdominal clinical applications.
- 3. Frequency :
- 4. Systems : compatible with the GE Logiq 400, 500 and 700 series ultrasound systems.
- Frequency – 4-8Mhz
- Convex – Neonatal head
- For L400/500
Note: Please note that provided info are for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy
- 5. Probe analysis
Connector : no dents cracks or bent pins, some scratches and paint loss
Lock : looks good
Cable : HAS some stains
HEAD AND handle : No dents and cracks, membrane appears to be nice , may has few scratches on the handle
SCAN ANALYSIS :
TAKE A LOOK ON MONITOR IMAGES FOR FUNCTIONALITY , Reviw Air scan (Image # 1 and 2 ) Phantom Scan (Image # 3) and Solid Organ scans (Image # 4) ......has dead crystals and weak elements
- Manual : No
- Case : No
- Cleaned : Yes
- Sterilized : No
- Shipping Weight: 7 lbs.
- Stocks ID: 11914(R2c3)
|
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition:
- 1. Overall Condition:- As seen in images : AS IS
- 2. Physical Condition: Please review images before bidding - Good
- 3. Working Condition: TAKE A LOOK ON MONITOR IMAGES FOR FUNCTIONALITY , Reviw Air scan (Image # 1 and 2 ) Phantom Scan (Image # 3) and Solid Organ scans (Image # 4) ......has dead crystals and weak elements ……We do not comment on the functionality of used probes, please review the images and take your own decision ............(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)