GE 548C (2175180) Convex Ar...
GE 548C (2175180) Convex Array Ultrasound Transducer Probe ~ 21562
YSTEM IS NOT INCLUDED IN THE SALE, IT HAS ONLY BEEN SHOWN TO DEMONSTRATE THE FUNCTIONALITY OF THE PROBE / Review the functionality images and make an informed decision after examining them closely / Has some shadows towards the left
Product details
Manufacturer | GE Healthcare |
Item: | GE 548C (2175180) Convex Array Ultrasound Transducer Probe |
Model/Cat # | 548C / 2175180 |
Serial No. | 44454VP7 |
Made In: | Japan |
Date of Manufacture: | 02-1998 |
Voltage: --
Short description...
- 1. Sale is for imaged items only.
- 2. Signs of High use
- 3. GE 548C (2175180) Convex Array Ultrasound Transducer Probe
Probe Analysis:
Connector: In good shape with no signs of bent or broken pins observed
Cable: Insulation of the cable has a faint tear on it as it seems to be slightly pulled near the handle
Head & handle: In good shape overall
Lock: Seems good and firm
Lens/Membrane: Has a faint chip on it that can be seen in the images
Functionality Analysis:
Air Scan: Has shadows towards the left, review functionality images
Phantom Scan: May have some weak elements, review images
Body Scan: Review the Body Scan performed > Review the Hepato-Renal Scan done by placing scan head at Right Upper Quadrant> Compare the echotexture of 2 solid organs. Review the Vascular Scan> performed by placing scan head at Right Carotid >Review the Lumen and Blood flow > Color flow looks good
*PLEASE CHECK FOR COMPATIBILITY BEFORE BIDDING FOR THE ITEM
***SYSTEM IS NOT INCLUDED IN THE SALE, IT HAS ONLY BEEN SHOWN TO DEMONSTRATE THE FUNCTIONALITY OF THE PROBE***
Package includes:-
GE 548C (2175180) Convex Array Ultrasound Transducer Probe
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
- 6. Sterilized : No
- 7. Manual : No
- 8. Cleaned : Yes
- 9. Shipping Weight : 10 lbs
Stock ID : 21562 (WH C12)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Fair
- 2. Physical Condition: Please review images before bidding : Fair
- 3. Working Condition: Has been tested at our end and the functionality has been shown in the image section, has dead element..will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)