GE 618C (2197485) Micro Con...
GE 618C (2197485) Micro Convex Array Ultrasound Transducer Probe ~ 21231
SYSTEM IS NOT INCLUDED IN THE SALE, IT HAS ONLY BEEN SHOWN TO DEMONSTRATE THE FUNCTIONALITY OF THE PROBE / In good shape / May have faint shadows / Review images and check for compatibility before bidding for the item / Cable has stains
Product details
Manufacturer | GE Health care |
Item: | GE 618C (2197485) Micro Convex Array Ultrasound Transducer Probe |
Model/Cat # | 618C / 2197485 |
Serial No. | 5342VP8 |
Made In: | USA |
Date of Manufacture: | 10-1999 |
Voltage: --
Short description...
- 1. Sale is for imaged items only.
- 2. Signs of average use
- 3. GE 618C (2197485) Micro Convex Array Ultrasound Transducer Probe
Probe Analysis:
Connector: In good shape with no signs of bent or broken pins observed
Cable: No cuts, tears or leakages observed on the cable has some stains on it
Head & handle: Seems to be in good shape with no signs of major cracks
Lock: Seems good and firm
Lens/Membrane: Completely free from nick and stains
Functionality Analysis:
Air Scan: Faint shadows observed towards the left, review functionality images
Phantom Scan: Weak elements observed, review images
Body Scan: Review the Body Scan performed > Review the Hepato-Renal Scan done by placing scan head at Right Upper Quadrant> Compare the echo-texture of 2 solid organs. Review the Vascular Scan> performed by placing scan head at Right Carotid .
*PLEASE CHECK FOR COMPATIBILITY BEFORE BIDDING FOR THE ITEM
***SYSTEM IS NOT INCLUDED IN THE SALE, IT HAS ONLY BEEN SHOWN TO DEMONSTRATE THE FUNCTIONALITY OF THE PROBE***
Package includes:-
GE 618C (2197485) Micro Convex Array Ultrasound Transducer Probe
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
- 6. Sterilized : No
- 7. Manual : No
- 8. Cleaned : Yes
- 9. Shipping Weight : 10 lbs
Stock ID : 21231 (WH C13)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Good
- 2. Physical Condition: Please review images before bidding : Good
- 3. Working Condition: Has been tested at our end and the functionality has been shown in the image section..will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
