Siemens ACUSON 8V3 Phased A...
Siemens ACUSON 8V3 Phased Array (Sector) Ultrasound Probe | Tested ~ 40051
Item specifics
- 8V3MPN07695740
Product details
Siemens ACUSON 8V3 Phased Array (Sector) Ultrasound Probe – Tested on ACUSON S2000
Item Overview
Pre-owned Siemens ACUSON 8V3 Phased Array (Sector) Ultrasound Probe in good cosmetic condition. Tested on a compatible Siemens ACUSON S2000 Diagnostic Ultrasound System (not included). The probe was recognized, initialized successfully, and demonstrated satisfactory B-Mode and Color Doppler performance.
Testing included an air scan, limited phantom scan, right carotid Color Doppler evaluation, and right upper-quadrant abdominal imaging.
Sale includes the probe only.
Device Information
Manufacturer: Siemens Medical Solutions USA, Inc.
Item: Phased Array (Sector) Ultrasound Probe
Model: 8V3 • Model No.: 07695740 • Serial No.: 61802504
Frequency Range: 8–3 MHz • IP Rating: IPX8 • DOM: 2006 • CE: 0123
Made In: Mexico
Condition Summary
Probe Housing & Handle
- Good cosmetic condition
- No major dents or structural cracks observed
- Minor scratches/scuffs consistent with normal prior use
- Handle is clean and structurally sound
Acoustic Lens
- Smooth and intact
- No cuts, tears, swelling, or delamination observed
Cable
- Approximately 7 ft long
- Flexible cable jacket
- No cuts, tears, or exposed wiring observed
- Strain reliefs intact
Connector
- Siemens pinless connector
- Connector housing in good condition
- Locking mechanism intact and functional
- Contact surface clean with normal cosmetic wear
Functional Testing
Test Platform: Siemens ACUSON S2000 Diagnostic Ultrasound System (not included)
Air Scan
- Probe recognized immediately
- Initialized successfully
- Uniform B-Mode image observed
- No obvious dropout or significant imaging artifacts noted
Phantom Scan
- Limited phantom evaluation performed
- Image appeared generally smooth
- Complete performance assessment was not possible using the available phantom
Color Doppler (Right Carotid)
- Right carotid artery evaluated
- Vessel lumen clearly visualized
- Appropriate Color Doppler fill observed
- Good blood-flow sensitivity demonstrated
- No obvious Doppler abnormalities noted during testing
Right Upper-Quadrant Imaging
- Probe positioned over the right upper quadrant
- Liver and right kidney successfully visualized
- Organ interfaces appeared well defined
- B-Mode image quality was satisfactory
The probe presets shown during testing included Pediatric Abdomen, Fetal Echo, Neonatal Head, and User Defined. Functional testing was performed using the Pediatric Abdomen preset.
Included
- Siemens ACUSON 8V3 Phased Array (Sector) Ultrasound Probe
Not Included
- Siemens ACUSON S2000 Diagnostic Ultrasound System
- Probe storage case
- User manual
- Original packaging
- Any accessories not shown
Cleaned / Sterilization
Cleaned: Yes • Sterilized: No • Reusable: Yes
Buyer Advisory
Please verify compatibility with your Siemens ACUSON ultrasound system before purchasing. This probe was tested only as described above. The ultrasound system shown in the listing photographs was used solely for testing purposes and is not included in the sale. Please review all listing photos carefully, as they form an important part of the item description.
Stock ID: 40051 (P.O. 2026) (OFH C7)