Philips L12-5 Linear Array ...
Philips L12-5 Linear Array Ultrasound Transducer (P/N 453561497452) ~ 39218
Item specifics
- Used
- Model
- L12-5MPN
- 453561497452
Product details
Manufacturer | Philips |
Item: | Philips L12-5 Linear Array Ultrasound Transducer (P/N 453561497452) |
Model/Cat # | L12-5 | Ref 453561497452 |
Serial No. | B1D6HK |
Made In: | China |
Date of Manufacture: | U/K |
Short Description:
Philips L12-5 linear array vascular ultrasound transducer tested on a compatible Philips system. Probe produces grayscale imaging and color Doppler. Lens shows edge wear with minor imaging imperfections. Suitable for basic or backup use. Please review all images carefully.
Condition Summary:
Probe Housing & Handle:
Good overall cosmetic condition. No cracks, dents, or structural damage observed. Minor surface wear consistent with normal use.
Acoustic Lens:
Edge wear and light surface scratches noted. Central lens area remains intact. No gross delamination observed. Cosmetic wear may contribute to minor imaging imperfections.
Cable & Strain Relief:
Approximately 7 ft cable. No cuts, kinks, or exposed wiring observed. Strain reliefs are intact and secure.
Connector (C-BORE Type):
Connector is clean and in good condition. No bent or missing pins noted. Locking mechanism is intact and firm.
Functionality / Testing Summary:
System Used:
Tested on compatible Philips ultrasound platform (not included)
Air Scan:
Uniform image produced with minor superficial artifacts. No complete image dropout observed.
Phantom Scan:
Consistent image with slight non-uniformity noted. No clear dead elements or major channel failure identified.
Vascular / Carotid Scan:
Right carotid artery visualized with grayscale and color Doppler
Color flow responsive and stable
No major signal dropout or voids observed
Overall Performance:
Probe is functional with stable image output and Doppler capability.
Minor imaging inconsistencies are present, likely related to lens wear.
What Is Included:
- Philips L12-5 Ultrasound Transducer (as shown)
What Is Not Included:
- Ultrasound system / console
- Phantom
- User manual
- Storage case
- Consumables / accessories
Buyer Advisory Note:
This probe shows lens wear and minor image inconsistencies.
Suitable for basic, training, or backup use.
Not recommended for precision-dependent or critical diagnostic applications.
Please review all images carefully and verify compatibility prior to purchase.
Shipping Note:
Item will be securely packaged and shipped with care.
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 39218 (PO 3034) (WH C15)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Good
- 2. Physical Condition: Please review images before bidding - Good
- 3. Working Condition: Tested on compatible Philips ultrasound platform (not included); Kindly review functionality images.....Will receive item as pictured…………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)