2017 Site-Rite Halcyon Ultr...
2017 Site-Rite Halcyon Ultrasound System Ref 950041600 W/ Probe & Cart ~ 39520
Item specifics
- Used
- Model
- 950041600MPN
- 950041600
Product details
Manufacturer | Bard Access Systems, Inc. |
Item: | 2017 Site-Rite Halcyon Ultrasound System 950041600 W/ 7.5MHz Probe & Rolling Cart |
Model/Cat # | 950041600 |
Serial No. | ST1707121 |
Made In: | USA |
Date of Manufacture: | 2017-08-31 |
Voltage: See Below
Short Description:
Bard Site-Rite Halcyon Ultrasound System mounted on a rolling medical cart with integrated storage and 7.5 MHz linear array probe. Unit powers on, passes self-test, and reaches the system functionality window. Demonstrated in multiple imaging modes as shown in listing photos.
Software Version: V1.00
Hardware Version: V1.00
System Version: V1.00
Power Requirement: 19V DC, 3.15A
AC/DC Adapter: Delta Electronics MDS-060AAS19 B Input: 100–250V AC, 50–60Hz
Condition Summary:
Main Console
- Minor cosmetic scratches from normal use.
- No dents or structural cracks noted.
- LED display is bright.
- Touchscreen is sensitive and responsive.
- Device powers on, passes self-test, and loads system menu.
- Date is correct; time may be adjusted per local time zone.
- No user manual available.
- No PM documentation available.
Battery
- Battery holds charge. After approximately 12 hours of charging, battery indicated ~40%.
- Battery health unknown. No warranty on battery runtime.
- System operates properly on AC power.
- Replacement recommended for long-term clinical use.
Connectivity (Left Side Panel):
Equipped with LAN (Ethernet), USB, VGA, S-Video, DC input, and active DICOM capability, with NTSC/PAL video configuration options; all ports appear intact and functional as shown.
Application & Software Interface:
Features multiple preset clinical applications (vascular, abdominal, cardiac, thyroid, etc.) with accessible tabs including DICOM (Active), System, Network, UI, Measure, and Maintenance functions; unit powers on, passes self-test, and reaches the system functionality window without errors.
Functionality / Testing Summary:
- Air Scan: Image visible with minor imperfections and slight gray areas noted.
- Phantom Scan: Image obtained; slight image variation observed.
- Vascular Scan: Right carotid lumen visualized. B-mode imaging demonstrates good structural clarity.
- Color Doppler: Color flow visualized; appears somewhat patchy.
- Overall system functionality demonstrated in images.
- Model: Site-Rite® Halcyon™ Linear Array Transducer with Buttons
- Frequency: 7.5 MHz (L75VA)
- Serial Number: 2017090013
- Date of Manufacture: 2017-09-21
- Bard medical equipment roll stand.
- Lockable drawer with keys included.
- Three segregated storage compartments.
- Integrated probe holder.
- Gel holder and accessory bins.
- Large lower wire basket.
- All wheels freely mobile.
- Storage unit and cart in very good cosmetic condition.
- Bard Site-Rite Halcyon Ultrasound System (P/N 950041600)
- 7.5 MHz Linear Array Probe
- Rolling Medical Cart with Storage
- Lockable Drawer with Keys
- Power Adapter
- Power Cord
- User manual
- Preventive maintenance records
- Additional probes
- Consumables or disposables
- No additional accessories beyond what is shown
Buyer Advisory Note:
Used medical device.
Probe housing crack present; probe is functional but replacement recommended.
Battery holds charge but health is unknown; no warranty on battery runtime.
Minor cosmetic wear consistent with prior use.
Date is correct; time may require adjustment per time zone.
Shipping Note:
Unit will be professionally packed to ensure safe transport.
For international shipments, we also offer custom crating for a flat fee of $300 to provide added protection during transit.
Please feel free to reach out if you’d like a shipping quote or have any questions — we’re happy to help coordinate the best option for your needs.
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 39520 (P.O 3034) (OH)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Good
- 2. Physical Condition: Please review images before bidding - Good
- 3. Working Condition: Has been tested at our end & is in good functionality....Will receive item as pictured ……………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)