Philips iE33 Xmatrix Ultras...
Philips iE33 Xmatrix Ultrasound System | C5-1, L9-3, S5-1 Probes | Printer~39018
Item specifics
- Used
- Model
- iE33XMPN
- 8500-0082
Product details
Manufacturer | Philips Healthcare / Philips Medical |
Item: | Philips iE33X Matrix Ultrasound System W/ C5-1, L9-3, S5-1 Probes + Sony UP-D897 Printer & Mitsubishi MD3000 VCR |
Model/Cat # | iE33X | Part Number: 8500-0082 |
Serial No. | 02XLZ0 |
Made In: | USA |
Date of Manufacture: | September 2008 |
Voltage: 100–127V / 220–240V~, 50/60Hz, 1010VA
Short description:
Philips iE33X Matrix ultrasound system configured for abdominal, cardiac, fetal, pediatric, vascular, and TCD applications. The system features a bright, scratch-free main LCD, dual responsive lower command touchscreens, height-adjustable control panel, and a fully functional articulating monitor arm. This package includes three transducers (C5-1, L9-3, S5-1), a Sony UP-D897 digital graphic printer, and a Mitsubishi MD3000 S-VHS ET VCR.
Regulatory Marks: CE Marked (CE 0086), CSA
Service Hardware: Rev E.3
Console Software Version: 6.02.144
Operating System: 3.0.0.1
Hardware Build: X.0
Chip ID: 00011d83204
System Configurations Present: Abdominal, Adult Echo, Fetal Echo, Pediatric Echo, Vascular, TCD
Annotation Libraries Installed: Abdomen, Adult Cardiac, Vascular, TCD
System Date/Time: Correct at time of testing (adjustable via system settings)
Condition:
- Main upper LCD: bright, clear, and scratch-free with no dense cracks observed
- Lower dual command LCDs: bright, sensitive, and fully responsive
- All soft pads, knobs, and buttons are intact and responsive
- Probe ports are in good condition
- Height-adjustable keyboard/control panel operates properly
- Articulating monitor arm moves smoothly and holds position
- Front foot lock engages correctly; all casters roll freely
- Speaker output verified during testing
- Keyboard commands register properly
Cosmetics:
- One visible crack noted on the right side of the main panel/control board area (see images )
- Left, right, and rear panels otherwise show no dents or structural damage
- May exhibit light scratches and scuffs consistent with normal prior clinical use
- System has been cleaned at our facility
Functionality:
Console
- Powers on normally and boots into operating software
- Air scans appear smooth with no visible gray banding or image dropouts
- Phantom scans (where applicable) appeared acceptable
Body scans performed for demonstration purposes only (see images):
Hepatorenal scan (RUQ): liver and kidney echotexture visualized
Carotid vascular scan: lumen and color flow demonstrated with satisfactory appearance
Images provided are for guidance only.
Included Transducers:
Probe #1 – Convex
- Model: C5-1 Reference #: 453561224466 Serial #: B83BGC Technology: PureWave
- Connector in good condition; no dents or cracks
- Cable approx. 8 ft, no cuts or tears noted
- Housing and lens in good condition
- Air scan smooth
- Phantom scan acceptable
- Body scan demonstrated (hepatorenal and carotid)
Probe #2 – Linear
- Model: L9-3 Reference #: 463661177102 Serial #: 032960
- Connector in good condition
- Cable approx. 8 ft, no cuts or tears observed; light cosmetic wear noted
- Handle and lens in good condition with no chips or cracks
- Air scan smooth
- Phantom scan acceptable
- Carotid vascular scan demonstrated with visible lumen and color flow
Probe #3 – Sector / Phased Array
- Model: S5-1 Reference #: 213148 Serial #: 0303XM
- Connector in good condition
- Cable approx. 8 ft, no cuts or tears noted (may show light cosmetic soiling)
- Handle intact; lens appears smooth
- Air scan appears acceptable
- Phantom scan not evaluated for this probe due to phantom limitations at our facility
Body scans demonstrated (hepatorenal and carotid for basic visualization)
All probes are offered as-is, having undergone basic functional verification only. Sector probe has not been evaluated for detailed cardiac diagnostics.
Peripherals:
Sony UP-D897 Digital Graphic Printer
- Powers on and displays ready status
- Soft keys responsive
- Unable to confirm printing from console at time of testing (possible loose or missing communication cable)
Mitsubishi MD3000 S-VHS ET VCR
- Powers on
- No further functional testing performed
- Philips iE33X Matrix ultrasound console (SN: 02XLZ0)
- C5-1 convex probe (Ref 453561224466, SN B83BGC)
- L9-3 linear probe (Ref 463661177102, SN 032960)
- S5-1 sector probe (Ref 213148, SN 0303XM)
- Sony UP-D897 digital printer
- Mitsubishi MD3000 VCR
- Integrated monitor, articulating arm, and height-adjustable control panel
- Power cord
- User manuals
- Software CDs / license media
- Printer paper or consumables
- VCR tapes
- Phantom
- Any accessories, probes, or cables not explicitly listed above
Buyer Advisory Note:
For international shipments, we also offer custom crating for a flat fee of $300 to provide added protection during transit.
Please feel free to reach out if you’d like a shipping quote or have any questions — we’re happy to help coordinate the best option for your needs.
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 39018 (P.O 2022) (WH 104)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: Has been tested at our end & is in good functionality....Will receive item as pictured ……………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
