For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

Philips S7-3T TEE Transesop...

Philips S7-3T TEE Transesophageal Ultrasound Probe 453561181214 W/ Case ~ 39019

Item specifics

Condition
Used
Seller Notes
“Pre‑owned Philips S7‑3T TEE ultrasound transducer with Deep‑C Bore connector, tested on a Philips iE33 system (console not included). Probe powers on and produces imaging output; angulation controls respond properly."
Model
S7-3T
MPN
453561181214

More details


$823.20

39019

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer

Philips Healthcare / Philips Medical

Item:

Philips S7-3T TEE Transesophageal Ultrasound Probe P/N 453561181214 W/ Case 

Model/Cat #        

S7-3T | Ref 453561181214 

Serial No.        

B15R6R 

Made In:             

USA

Date of Manufacture:  

U/K

                   

Short description:

Philips S7-3T TEE ultrasound transducer supplied with storage case, connector cover, and scan head cover. Probe powers on through Philips iE33 system and produces imaging output. Mechanical controls respond appropriately. Offered with basic functional verification only.

Connector Type: Deep-C Bore (with protective connector cover)
Compatibility Tested With: Philips iE33 Ultrasound System (console not included)

 

Condition Summary:

 

  • Probe body in good overall condition with no dents or structural cracks observed
  • Lens face appears smooth; no visible chips or fractures
  • External markings remain intact
  • Angulation/steering mechanism responsive
  • Insertion tube straight with no buckling, cuts, or tears noted
  • Connector housing shows no dents or cracks; locking mechanism intact and functional
  • Connector cover present
  • Cable approx. 7 ft in length with no cuts or tears; strain relief intact
  • May exhibit light cosmetic scratches and scuffs consistent with prior clinical use
Storage Case:
  • Hard storage case included (no keys)
  • Exterior intact; foam insert present and showing mild age-related wear
  • Handle and latches intact

 

 

Functionality / Testing Summary:

 

  • Probe recognized and powered by Philips iE33 system
  • Air scan performed (see uploaded images)
  • Phantom scan attempted; unable to assess due to limitations of phantom available at our facility (phantom images uploaded for reference only)
  • Limited body scan performed by placing scan head at right carotid for basic visualization

Testing Limitations:

  • No adult or pediatric cardiac echocardiography performed
  • Doppler/color flow not evaluated
  • No EKG-gated testing performed
  • No calibration completed
  • No formal performance verification or diagnostic accuracy testing performed

This probe has undergone basic power-on and limited imaging verification only.

 

 

What Is Included:

 

  • Philips S7-3T TEE Probe (P/N 453561181214, SN B15R6R)
  • Protective connector cover
  • Scan head cover
  • Hard storage case with foam insert

 

 

 

What Is Not Included:

 

  • Ultrasound console (Philips iE33 shown for testing only)
  • Mouth guards / bite blocks
  • User manuals
  • Calibration documentation
  • Physiological cables or EKG accessories
  • Consumables or disposables
  • Storage case keys
  • Any additional accessories not explicitly listed

 

 

Buyer Advisory Note:
This TEE probe is sold as-is with limited in-house testing performed. Only basic power-on, air scan, phantom attempt, and minimal carotid visualization were completed using a Philips iE33 system (not included). Full cardiac functionality, Doppler performance, and clinical suitability have not been verified. Buyer is strongly advised to have this probe professionally inspected, calibrated, and certified by qualified biomedical personnel prior to any clinical application.

Shipping Note:
Probe will be shipped in its storage case with additional protective packaging. Buyer is responsible for shipping costs and any specialized delivery requirements.

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*

Stock ID : 39019 (P.O 2022) (SC 9)

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition: As seen in images - Very Good
  2. 2.    Physical Condition: Please review images before bidding - Very Good
  3. 3.    Working Condition: This probe has undergone basic power-on and limited imaging verification only......Will receive item as pictured…………(Offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)