Manufacturer | Toshiba Medical Systems Corporation |
Item: | 2009 Toshiba PLT-1202S Linear Array 12MHz Ultrasound Transducer Probe |
Model/Cat # | PLT-1202S |
Serial No. | 99A0992504 |
Made In: | Japan |
Date of Manufacture: | 09-2009 |
Short description:
Toshiba PLT-1202S is a 12 MHz linear array transducer designed for vascular, small parts, musculoskeletal, and superficial imaging applications. It is compatible with Toshiba ultrasound consoles and recognized by the system during testing.
Frequency: 12 MHz (as indicated on probe cap)
Regulatory Marks: CE 0197
Connector Type: Cannon multipin connector (shown in images)
Cable Length: Approximately 10 feet
- Probe Type: Convex (abdominal/general use)
- Frequency: 5.0 MHz (T5.0)
- Scan Mode: 2D / Color Doppler capable
- System Display ID: 6CV1
- Compatible with Toshiba ultrasound consoles
Cosmetic Condition:
- Probe Housing & Handle: Overall good cosmetic condition, but a small dent noted on the probe corner (shown in images). Some light scratches and scuffs present from prior use.
- Acoustic Lens: Appears smooth and intact.
- Cable: Approximately 10 feet long, no cuts, tears, kinks, or buckling, only minor surface dirt.
- Strain Relief: Both ends are intact, free of tears, and in very good condition.
- Connector: No dents or cracks, minor surface scratches only. Pins are intact, no bent or missing pins. Lock mechanism is firm and stable.
Functionality Summary:
- The probe was tested with a Toshiba console.
- System Recognition: Probe was correctly identified as PLT-1202S.
- Preset Used: Carotid examination.
- Image Quality: Air scan appeared smooth with minor imperfections. Phantom imaging looked consistent and smooth. Carotid body scan showed fair blood flow visualization, though somewhat patchy.
- Assessment: Functional and usable for general exams where high-level color flow analysis is not required.
What’s Not Included:
- Ultrasound system/console
- User manual
- Phantom
- Carrying case
- Consumables or disposables
Package includes:
2009 Toshiba PLT-1202S Linear Array 12MHz Ultrasound Transducer Probe
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Sterilized : Non-sterile
Manual : Not Included
Cleaned : Yes, at our facility
Shipping Weight : 10 lbs
Stock ID : 37935 {P.O 2019} (WH104-SCC12)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Good
- 2. Physical Condition: Please review images before bidding - Fair
- 3. Working Condition: Not ideal for detailed examination...Will receive item as pictured…………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)