2013 CUBEscan BioCon-700 Bladder Scanner | Battery Error | PARTS/REPAIR ~ 37759

Item specifics

Condition
For parts or not working
Seller Notes
“This is a used BioCon-700 CUBEscan Bladder Volume Measurement System by Mcube Technology.The touchscreen is bright and responsive, and the built-in printer appears functional, though printer paper is missing.”
Model
BioCon-700
MPN
MUM-Biocon-700

More details


$117.60

37759

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

 

Manufacturer

Mcube Technology Co., Ltd.

Item:

2013 CUBEscan BioCon-700 Bladder Scanner | ONLY 

Model/Cat #        

BioCon-700 | Ref MUM-Biocon-700 

Serial No.        

BC700-F2109708 

Made In:             

South Korea 

Date of Manufacture:  

2013-02 

Voltage:                  DC 9V, 3.0A

Short description:

BioCon-700 CUBEscan Bladder Volume Measurement System by Mcube Technology. Bright and responsive touchscreen unit with built-in printer. Device powers on and navigates through all menus, but shows a battery error and will require battery replacement. Adapter Model (Required): JMW128K-A090XXX. Cosmetic wear is present. Offered as-is for parts or repair. 

Cosmetic Condition:

  • Overall fair cosmetic condition.
  • Screen is bright, responsive, and mostly scratch-free, with one visible blemish located on the LCD screen in the upper right corner.
  • Faint crack on the front bezel between the power button and indicator light.
  • Chips on the upper and lower left corners of the device. - left sided device handle is broken 
  • Scuffs and scratches are present on both the front bezel and rear housing.
  • Rear shows cosmetic wear near the printer compartment and a faint housing crack.
  • Printer door intact but no paper is included. 

Functionality Summary:

  • Unit powers on and responds to all touchscreen menu commands: SCAN, REVIEW, SETUP, USER, DEVICE, POWER, and DATE/TIME.
  • Interface displays correct date (07-24-2025); time can be adjusted.
  • Battery Error [E005] appears intermittently — internal battery is dead and must be replaced.
  • Printer appears functional (feed button responds), but no paper included.
  • No SD card installed.
  • Imaging setup shows last Cal Kit date: 02-09-2022 and Phantom Cal date: 12-14-2015calibration is recommended before clinical use.
  • Volumetric probe is not included, so actual scanning function was not tested.
  • Device is sold as-is with no warranty implied or expressed

What’s Not Included:

  • Volumetric bladder probe
  • AC/DC adapter (Model JMW128K-A090XXX)
  • SD memory card
  • User manual
  • Printer paper
  • Cart or stand
  • Gel, calibration certificate, consumables, or disposables 

Package includes:


2013 CUBEscan BioCon-700 Bladder Scanner ONLY | Battery Error 


*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*


Sterilized Non-sterile device

Manual : Not Included

Cleaned : Yes, at our facility

Shipping Weight : 15 lbs

 

Stock ID : 37759 (P.O 2017) (WH104 SCC8)

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: PARTS ONLY, please refer to images for cosmetic condition.

  1. 1.    Overall Condition: As seen in images - Fair
  2. 2.    Physical Condition: Please review images before bidding - Fair
  3. 3.    Working Condition: Sold AS-IS | Parts Only...Will receive item as pictured…………(Offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)