Parks Model 915 Dual-Freque...
Parks Model 915 Dual-Frequency Doppler System Probes ~ 37708
Item specifics
- Used
Product details
Manufacturer | Parks Electronics Laboratory |
Item: | Parks Model 915 Dual-Frequency Doppler System w/ 10 MHz & 2 MHz Probes |
Model/Cat # | 915 |
Serial No. | N/A |
Made In: | USA |
Date of Manufacture: | U/K |
Probe Frequencies: 2 MHz and 10 MHz
Short description:
This used Parks 915 Doppler unit features dual-frequency functionality (2 MHz & 10 MHz) with a tested 10 MHz probe producing audible tones. The 2 MHz probe is untested but in good cosmetic shape. Includes a depleted rechargeable battery (Model 126), though the AC adapter is not included. All knobs, ports, and structural components are intact, and the device shows only minor cosmetic wear.
Battery Details:
- Battery is depleted and must be replaced or recharged externally
- Device does not include the AC adapter/charger
- Battery compartment fits the Model 126 battery, appears clean and undamaged
- Battery warning labels present: Do NOT use device on patients while charging and avoid overcharging (more than 15 hrs)
Ports & Knobs Description:
- Probe Selector / Power Knob – Toggles between 2 MHz, OFF, and 10 MHz
- Volume Knob – Responsive
- Cautery Suppressor Knob – Present and intact
- Recharge/Battery Voltage Meter – Functional
Ports:
(2) Probe input jacks (2 MHz and 10 MHz)
(1) Charger input
(1) Earphones jack
Condition & Functionality Summary:
- Cosmetic Condition: Good used condition with minor scuffs and surface scratches
- Top carrying handle and bottom rubber bumpers are intact
- All knobs and ports are structurally sound
- 10 MHz probe tested and produces audible Doppler signal when used with a compatible power source
- 2 MHz probe is visually intact with no dents, tears, or cracks; not tested
- Cables and strain reliefs on both probes are tear-free
Advisory Note:
- Battery is depleted or dead – must be replaced before clinical use
- No AC adapter, headphones, gel, manual, consumables, or disposables included
Cautions & Warnings – Parks Model 915 Doppler:
- Do NOT use the device on patients while connected to charger.
- Charge battery only when meter shows need; do not overcharge (max 15 hrs).
- Avoid flammable gases during operation or charging.
- Use only ultrasonic gels (e.g., Aquasonic). No ECG paste, K-Y Jelly, or Vaseline unless necessary.
- Do not autoclave probes. Use gas sterilization only.
- Probe cables are sensitive—avoid frequent disconnects.
- Battery life: 2–3 years. Recharge overnight when needed.
- For precordial probe, use flat side with semicircle crystals; place with cable at right angle to blood flow.
- Cautery Suppressor: Cuts sound during cautery noise; adjust with right knob.
Package includes:
Parks Model 915 Dual-Frequency Doppler unit
One 10 MHz Pencil Probe
One 2 MHz Probe
Rechargeable battery pack (Model 126)
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Sterilized : Non-sterile
Manual : Not Included
Cleaned : Yes, at our facility
Shipping Weight : 30 lbs
Stock ID : 37708 (P.O 2010) (SC 2)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding : Very Good
- 3. Working Condition: Has been tested at our end & is in good functionality...will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.