Philips IU-22 S4-1 Phased A...
Philips IU-22 S4-1 Phased Array Ultrasound Probe 4000-0966-02 (TESTED) ~ 36675
Item specifics
- Used
- Model
- S4-1MPN
- 4000-0955-02
Product details
Manufacturer | Philips |
Item: | Philips IU-22 S4-1 Phased Array Ultrasound Probe 4000-0966-02 (TESTED) |
Model/Cat # | S4-1 |
Serial No. | 0211VJ |
Made In: | USA |
Date of Manufacture: | U/K |
Short description...
- 1. Sale is for imaged items only.
- 2. Signs of average use.
- 3. Philips IU-22 S4-1 Phased Array Ultrasound Transducer Probe 4000-0966-02
*CE# 0086
*No manual, case, phantom, consumables or disposables included
Probe Analysis:
Connector: No sign of broken or bent pins, has a few scratches on it
Cable: Tear noted (see images) involving insulation only
Head & handle: In good shape overall may have a few scratches on it
Lock: Seems good and firm
Lens/Membrane: Appears to be smooth, review images
Functionality Analysis:
Air Scan: Faint shadows maybe, please review images
Phantom Scan: Seems smooth, unable to assess
Body Scan: Kindly take a look at the Body Scan performed > Review the Hepato-Renal Scan done by placing scan head at Right Upper Quadrant > Compare the echo-texture of 2 solid organs. Review the Vascular Scan > performed by placing Scan Head at Right Carotid > Review the Lumen and Blood flow > Color flow looks fair. Cardiac exam not performed
*PLEASE CHECK FOR COMPATIBILITY BEFORE BIDDING FOR THE ITEM
***SYSTEM IS NOT INCLUDED IN THE SALE, IT HAS ONLY BEEN SHOWN TO DEMONSTRATE THE FUNCTIONALITY OF THE PROBE***
NOTE: NOT IDEAL FOR DETAILED EXAMS
Package includes:-
Philips IU-22 S4-1 Phased Array Ultrasound Probe 4000-0966-02 (TESTED)
- 6. Sterilized : No
- 7. Manual : No
- 8. Cleaned : Yes
- 9. Shipping Weight : 10 lbs
Stock ID : 36675 (P.O 2016) (SC 8)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Good
- 2. Physical Condition: Please review images before bidding - Fair
- 3. Working Condition: Has been tested at our end and the functionality has been shown in the image section, review the images and make an informed decision.....Will receive item as pictured…………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)