2013 Philips IU22 Xmatrix U...
2013 Philips IU22 Xmatrix Ultrasound W/ C5-1, X6-1 & CD9-3V Probes HW G.1~ 33897
Item specifics
- Used
- Model
- IU22MPN
- IU22
Product details
Manufacturer | Philips Healthcare |
Item: | Philips IU22 Diagnostic Xmatrix Ultrasound W/ C5-1, X6-1 & CD9-3V Probes; UP-D897 Printer & CDs |
Model/Cat # | IU22 / 8500-0064-02 |
Serial No. | BOG2GG |
Made In: | USA |
Date of Manufacture: | 2013-01-18 |
Voltage: 100-240V 1010VA 50-60Hz
Short description...
- 1. Sale is for imaged items only.
- 2. Signs of average use
- 3. Has been tested at our end & is in good functionality as shown in the images
- A. Philips IU22 Xmatrix Diagnostic Ultrasound Console HW G.1
*CE # 0086
*System was under use till end last year
*Regular PM Done by Philips & Siemens
*Last Two PM in 2023 & 2022
*Software 6.3.2.2
*Service Hardware Rev HW G.1
*Installed parameter options: Small parts, OB/GYN, Premium basic 3D & 3D/4D Imaging, 3D Color, Live 3D, Live Xplane, Netlink, DiCom 3.0, QLab 3DQGI, Smart exam
*Both LCDs are bright & crack free
*Bottom LCD is touch sensitive
*Top wide screen is scratch free
*All softpads are intact; none missing
*All knobs are resposnive
*3 probe slots are in good shape
*Height is adjustable
*One crack noted on main board (see images with pointed finger)
*Articulating arm is doing well
*No panel cracks noted
*Enjoys lockable wheels with push lever
*Speaker seems working
*Keyboard keys are commanding
B. Probes:
1- Philips C5-1 Convex array Ultrasound probe Ref 453561224466; SN# BA3BGC (purewave technology)
*Probe Analysis:
*Connector: In good shape, no broken or bent pins, no dents or cracks
*Cable: Free form cuts, tears or leakages of all sort; slightly yellowed
*Head & Handle: Has some scratches
*Lens: Appears to be smooth
*Functionality Analysis:
*Air Scan: Smooth, review images
*Phantom Scan: Smooth, review images
*Body Scan : Examine the images and make an informed decision by yourself. Images are for guidance use only
Kindly take a look at the Body Scan performed > Review the Hepato-Renal Scan done by placing Scan Head at Right Upper Quadrant (RUQ) > Compare the ECHOTEXTURE of TWO SOLID organs (i.e Liver and Kidney)
Review the Vascular Scan > performed by lacing Scan Head at Right Carotid > Review the Lumen and Blood flow > Color flow looks Good.
2- Philips X6-1 Matrix Array Ultrasound Probe Ref 453561247502; SN# B0JR1W
*Probe Analysis:
*Connector: In good shape
*Cable: Free form cuts, tears or leakages of all sort
*Head & Handle: In good shape
*Lens: Appears to be smooth
*Functionality Analysis:
*Air Scan: review images
*Phantom Scan: Unable to access
Body Scan : Examine the images and make an informed decision by yourself. Images are for guidance use only
Kindly take a look at the Body Scan performed > Review the Hepato-Renal Scan done by placing Scan Head at Right Upper Quadrant (RUQ) > Compare the ECHOTEXTURE of TWO SOLID organs (i.e Liver and Kidney) .
Review the Vascular Scan> performed by placing Scan Head at Right Carotid >Review the Lumen and Blood flow > Color flow looks good
3- Philips 3D9-3V Endocavity probe Ref 45356122115; SN# B0J7QP
*Probe Analysis:
*Connector: In good shape, no dents or cracks noted
*Cable: Free form cuts, tears or leakages of all sort
*Head & Handle: In good shape
*Lens: Appears to be smooth
*Functionality Analysis:
*Air Scan: Smooth, review images
*Phantom Scan: Smooth, review images
*Body Scan: Review the Hepato Renal Scan done just to eluicidate the functionality
NO OTHER SCANS PERFORMED
PROBES ARE BEING OFFERED AS IS
C. Sony Digital UP-D897 Printer Included
*All softpads are intact, responsive & working
*No additional paper included
D. Included CDs are:
*1X Preset backup +LO ; 2018
*1X backup NO -LO ; 2019
*1X backup preset +LO File 2019
*1X backup preset +LO File 2020
*1X backup preset 2022
*1X SW Backup +LO File 2023
E. No paper, accessories, cables, USB, disks or manual included
*Please review images and check for compatibility before bidding for the item
Package includes:-
2013 Philips IU22 Xmatrix Diagnostic Ultrasound Console
Philips C5-1 Convex array Ultrasound probe
Philips X6-1 Matrix Array Ultrasound Probe
Philips 3D9-3V Endocavity probe
Sony Digital UP-D897 Printer
CDs
Power Cord
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
- 6. Sterilized : No
- 7. Manual : No
- 8. Cleaned : Yes
- 9. Shipping Weight : 300 lbs
Stock ID : 33897 (P.O 1200) (WH)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding : Very Good
- 3. Working Condition: Has been tested at our end & is in good functionality....Will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)