2010 Smith & Nephew DYONICS...
2010 Smith & Nephew DYONICS 25 Fluid Management System – Error Screen ~ 39232
Item specifics
Product details
Manufacturer | Smith & Nephew, Inc. |
Item: | Smith & Nephew DYONICS 25 Fluid Management System– Error Screen |
Model/Cat # | 25 | Ref 7211010 |
Serial No. | ZN04768 |
Made In: | USA |
Date of Manufacture: | 2010 |
Voltage: 100–120 / 200–240 VAC 50/60 Hz 300 VA
Short Description:
Smith & Nephew DYONICS 25 Fluid Management System. Unit powers on and completes startup sequence but displays cassette-related error. Touchscreen is non-responsive, preventing navigation. Offered as-is for parts or repair.
Condition:
- Good pre-owned condition
- No dents or cracks observed
- Minor scratches and scuffs from normal use
- Labels and data plate legible
- LCD screen is bright and clear
- No visible damage
- Solid enclosure
- Feet intact and stable
- No structural damage
- Cooling fan intact with guard
- Ports and connectors present
- Power inlet intact
- Power button functional
- Touchscreen responsiveness untested
Functionality Summary:
Power-On Testing:
- Unit powers on successfully
- Completes boot process
- Displays DYONICS interface
Operational Behavior:
- Screen prompts for cassette insertion
Error Observed:
- CASSETTE INSERTION / PRESSURE OFFSET ERROR
- Remove cassette
- Restart control unit
- Fully insert cassette
- Remove cassette
Control Limitation:
- Screen goes directly to error state
- Touchscreen's responsiveness is untested
Testing Limitation:
- No cassette available
- No fluid system connected
- No further testing possible
What’s Included:
- Smith & Nephew DYONICS 25 Fluid Management System
- Integrated power cord
What’s Not Included:
- Cassette(s)
- Tubing sets / accessories
- Footswitch
- User manual
- Consumables / disposable items
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 39232 (P.O 1200) (R3 C11)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: Parts / Repair, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - AS IS
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: Unit powers on but is non-functional due to touchscreen issue and cassette error......Will receive item as pictured…………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)