Aesculap Prestige 8360-10 A...
Aesculap Prestige 8360-10 Atraumatic Laparoscopic Grasper | 5mm x 36cm ~ 37796
Item specifics
- Used
- Model
- 8360-10MPN
- 8360-10
Product details
Manufacturer | Aesculap |
Item: | Aesculap Prestige 8360-10 Atraumatic Laparoscopic Grasper | 5mm x 36cm | Rotatable Insulated Shaft | Double Action |
Model/Cat # | 8360-10 |
Serial No. | N/A |
Made In: | Germany |
Date of Manufacture: | U/K |
Short description:
The Aesculap Prestige 8360-10 is a 5 mm, 36 cm atraumatic laparoscopic grasper designed for precision in minimally invasive surgery. This version features a rotatable insulated shaft and double-action serrated jaws but is the non–flush port variant of the Prestige series.
Series: Prestige Portfolio
Instrument Type: Atraumatic Laparoscopic Grasper
Shaft: Rotatable, insulated
Diameter: 5 mm
Length: 36 cm
Design: Double-action jaws, ergonomic Prestige handle, without flush port
Specifications:
- Jaw Type: Atraumatic, double-action, serrated for secure grip
- Rotation: Fingertip rotation knob for 360° shaft rotation
- Insulation: Black insulated shaft for electrical safety
- Handle: Scissor-style ergonomic Prestige handle, non-ratcheting
- Flush Port: Not present on this unit
Condition:
- Pre-owned, in good cosmetic and functional condition
- Shaft insulation intact, no cracks noted
- Jaws align well, serrations intact, showing minimal wear
- Handle and rotation knob move smoothly
- Some light surface scratches and signs of use consistent with prior handling
- No structural damage observed
Functionality Summary:
- Jaws open and close fully with good gripping strength
- Rotation knob turns smoothly for controlled positioning
- Insulated shaft intact
- Mechanically tested; not clinically tested
Package includes:
Aesculap Prestige 8360-10 Atraumatic Laparoscopic Grasper | 5mm x 36cm
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Sterilized : Non-sterile
Manual : Not Included
Cleaned : Yes, at our facility
Shipping Weight : 6 lbs
Stock ID : 37796 (P.O 2019) (R3 C6)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Good
- 2. Physical Condition: Please review images before bidding : Good
- 3. Working Condition: Has been tested at our end & is in good functionality...will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)