For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

2010 Zonare Z.One UltraSoun...

2010 Zonare Z.One UltraSound System W/ Scan Engine,P4-1,P4-1c & CW Probe ~ 22965

Item specifics

Condition:Used : 
Notes:Has been tested at our end & the unit is in very good functionality / Comes with Zonare Z.One scan engine & various ultrasound transducer probes
Model:

Z.One

Brand:

Zonare

More details


$3,436.00

22965

Availability: This product is no longer in stock.

Product details

Manufacturer

Zonare

Item:

2010 Zonare Z.One UltraSound System W/ Scan Engine,P4-1,P4-1C & CW Probe

Model/Cat #        

Z.One

Serial No.        

18695207D

Made In:             

USA

Date of Manufacture:  

1-11-2010

Voltage: --

                   

Short description...

  1. 1.      Sale is for imaged items only.
  2. 2.   Signs of careful use
  3. 3.   Has been tested at our end & the functionality has been shown in the image section

     *Cosmetically the unit is in very good shape with no cracks, dents or scuffs of any sort

     *May have a few minute scratches on it since it has been owned previously

     *Software Version: 4.3.118D

     *BATTERY SEEMS TO BE DEAD for SCAN ENGINE & WILL NEED TO BE REPLACED PRIOR TO USE 

     *No printer with the system.

     *Comes with quick reference guide, 2X keys& 3X probes:


Zonare P4-1 Phased Array Ultrasound Transducer Probe: 


Probe Analysis:


Connector:            In good shape overall, review images.

Cable:                    No sign of cuts, tears or leakages of any sort, review images

Head & handle:    Appears to be in good shape, review images

Lock:                     Seems to be intact firmly

Lens/Membrane:  Completely free from nicks & tears, review images


Functionality Analysis:  (IMAGE 4)


Air Scan: Faint shadows maybe, please review images

Phantom Scan: Unable to assess, review images provided

Body Scan : Kindly take a look at the Body Scan performed > Review the Hepato-Renal Scan done by placing Scan Head at Right Upper Quadrant (RUQ) > Compare the ECHOTEXTURE of  TWO SOLID organs (i.e Liver and Kidney). Review the Vascular Scan> performed by placing Scan Head at Right Carotid > Review the Lumen and Blood flow > Color flow looks patchy. Examine the images and make an informed decision by yourself. Images are for guidance use only

Due to PATCHY color flow, PROBE does not look a good candidate for Cardiac EXAMS 

 

Zonare P4-1c Phased Array Ultrasound Transducer Probe:

 

Probe Analysis:


Connector:            In good shape overall, review images.

Cable:                    No sign of cuts, tears or leakages of any sort, review images

Head & handle:    Appears to be in good shape, review images

Lock:                     Seems to be intact firmly

Lens/Membrane:  Completely free from nicks & tears, review images


Functionality Analysis: (IMAGE 5)


Air Scan: Faint shadows maybe, please review images

Phantom Scan: Unable to assess, review images provided

Body Scan : Kindly take a look at the Body Scan performed > Review the Hepato-Renal Scan done by placing Scan Head at Right Upper Quadrant (RUQ) > Compare the ECHOTEXTURE of  TWO SOLID organs (i.e Liver and Kidney). Review the Vascular Scan> performed by placing Scan Head at Right Carotid > Review the Lumen and Blood flow Color flow looks very poorExamine the images and make an informed decision by yourself. Images are for guidance use only.

     *Please review images and check for compatibility before bidding for the item

Due to POOR color flow, PROBE does not look a good candidate for Cardiac EXAMS 


NOTE:

  1. 1.    ALL THE PROBES ARE OFFERED AS IS, WHERE IS. FUNCTIONALITY HAS BEEN SHOWN IN THE IMAGE SECTION FOR GUIDANCE PURPOSES. THEY MAY OR MAY NOT HAVE WEAK ELEMENTS THEREFORE IT IS THE BUYER'S RESPONSIBILITY TO REVIEW THE IMAGES & THE DESCRIPTION BEFORE COMMITING TO BUY THE SYSTEM.
  2. 2.   BATTERY OF THE SCAN ENGINE IS DEAD & WILL NEED TO BE REPLACED PRIOR TO USE IF INTEDED TO USE ON BATTERIES. HAS NOT BEEN REMOVED FROM THE CART & FUNCTIONALITY WAS CHECKED WHILST THE ENGINE WAS ON THE SMART CART.
  3. 3.    SOFTWARE UPDATE STATUS IS UNKNOWN
  4. 4.    WHEN PURCHASING A USED PIECE OF EQUIPMENT, IT MUST BE KEPT IN MIND THAT SINCE IT HAS BEEN OWNED PREVIOUSLY, THE UNIT MAY HAVE SOME SIGNS OF USAGE ON IT LIKE SCRATCHES & NORMAL WEAR & TEAR. 




SHIPPING NOTE:

Our shipping charges are flat for Lower 48 states.

You are more than welcome to use your own shipper

In that case a handling fee of 100 USD would Apply 

 

In that fee, we will Palletize the item, Bubble wrap, Shrunk wrap, strap and cardboard the item. 

 

    Package includes:-


Zonare Z.One Scan Engine Diagnostic Ultrasound System

Zonare 80044-00 Battery (S.N: 02604B107K)

Zonare CB-83340 ECG/EKG Cable W/ Three-Leads

Zonare P4-1 Phased Array Ultrasound Transducer Probe (S.N: 01243P3X107A)

Zonare P4-1C Phased Array Ultrasound Transducer Probe (S.N: 01289P4X108)

Zonare 86000-00 PENCIL Probe 

Quick Reference Guide

2X Keys

Software Backup Stick

 

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*


  1. 6.        Sterilized No
  2. 7.        Manual : No
  3. 8.        Cleaned : Yes
  4. 9.        Shipping Weight : 150 lbs

 

Stock ID : 22965 (WH111)

 

 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition:- As seen in images  - Very Good
  2. 2.    Physical Condition:  Please review images before bidding : Very Good
  3. 3.    Working Condition: Has been tested at our end & the functionality has been shown in the image section...will receive item as pictured ……………(offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  6. 6.    Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.