For orders, please call: 1-952-953-0653

$812Checkout 5 Item(s)

MENU

    

Toshiba iStyle Aplio XG Dia...

Toshiba iStyle Aplio XG Diagnostics Ultrasound Machine W/ Probes & Printer~16777

Item specifics

Condition:Used : 
Notes:Overall condition seems to be Very good / Comes with 3 X probes / Also comes with Sony Printer / Doesn't come with manuals
Brand:

Toshiba

Image Color:Color
Model:

SSA-790A

Ultrasound Machine Features:Printer

More details


$6,316.00

16777

Availability: This product is no longer in stock.

Product details

Manufacturer :

Toshiba Ultrasound 

Item:

Aplio XG Diagnostics Ultrasound Machine by Toshiba W/ 3 X Probes & Printer

Model/Cat #

SSA-790A

Serial No.

99F044536

Made In:

Japan

Date of manufacture

04-2009

Voltage : 120V 12A 60Hz

**Details provided below have been entered to the best of our knowledge. However they still remain prone to minor errors caused while listing** 

Feel free to contact us for further information regarding the machine


Short description…

  1. 1.        Sale is for imaged items only.
  2. 2.        Signs of careful use

Software version : HDD Version V5.21 *R505

  1. 3.    Comes with 3X probes: Probes are offered in AS IS condition 

-Toshiba PLT-1204AT Linear Array Probe ~ 15719 

Serial No. 99A1162535, DOM : 06-2011

Bandwidth: 7-14 MHz, Center of Frequency: 12 MHz , Applications: Vascular & Small Parts , MSK , PVS , CVS Breast Thyroid 

Probe analysis:  Connector has no dents or cracks, No bent pins but may has scratches, .....minor chip loss , ITT DLM-360P connector , Lock looks fine ,  Cable may has some stains....no cuts or tears ,  Probe handle and head may has scratches , Acoustic lens is smooth ............chipped at one corner of nose 

Scan analysis : Image  # 6 & 7

Air Scan :few shadows, Phantom scan, weak elements , Vascular scan : Patchy Blood flow 


-Toshiba PVT-382BT Convex Ultrasound Probe ~ 15701 

Serial No.99A1034481, Made In:Japan, Date of manufacture, 2010-

Bandwidth: 1.8 – 5.5 MHz, Center of Frequency: 3.5 MHz, Frequency Selection: 5.5 MHz, 3.7 MHz, 1.8 MHz. THI Frequency Selection: 5.0 MHz, 3.8 MHz, 2.8 MHz, D-THI Frequency Selection: 5.0 MHz, Field of View: Approx. 80o, Biopsy Guide: UAGV-027A ,   Applications: Abdominal

Probe analysis: Connector has no dents or cracks, No bent pins but may has scratches, ITT DLM-360P connector , Lock looks fine ,  Cable may has some stains  and has no cuts or tears,  Probe handle and head may has scratches , Acoustic lens is smooth

Scan analysis : Image  # 4 & 5

 

Air Scan :Shadows ?, Phantom scan: smooth  , Body scan : Hepatorenal scan 

May or may not have weak elements


-Toshiba PLT-704AT Linear Array Ultrasound Probe ~ 16352 

Bandwidth: 7-14 MHz, Center of Frequency: 7.5 MHz, 38mm

 Applications: Vascular & Small Parts 

Probe analysis: Connector has no dents or cracks, No bent pins but may have scratches, ITT DLM-360P connector , Lock looks fine ,  Cable may has some stains  No cuts or tears ,  Probe handle and head may have scratches , Acoustic lens is smooth Scan analysis : Image  # 8 & 9


Air Scan :few shadows, Phantom scan : weak elements , Vascular scan : Good  blood flow , may have weak elements 


Image Breakdown is as follows:

*Image 1  = Main image showing the overall machine + the printer functionality

*Image 2  = Shows the complete preset screen 

*Image 3  = 3 Probes attached to the machine

*Image 4  = Convex Probe Air scan

*Image 5  =  Convex Probe Body scan, hepatorenal scan 

*Image 6  = Linear Probe Air scan 

*Image 7  = Linear Probe vascular scan 

*Image 8  = Linear Probe Air scan 

*Image 9  = Linear Probe Body Scan (Colored Output)

*Image 10= Showing the probes attached and the cosmetic condition of the machine 

*Image 11= Shows the rear-end of the machine

*Image 12= Shows the complete side of the machine 

 

Doesn't come with manuals

TA 700 LCD Display P/N# BSM31-8013 S/N# 23815039 DOM# 03-03-2009

Console may have some scratches but no major dents or chips are seen

All probes are offered AS IS, they may have some issues refer to images for output quality

Sony UP 897 Digital Printer (Working) functionality can be seen in the images attached


*Kindly review the images thoroughly and see them with zooming to get complete knowledge about the minute details that we may have overlooked*


We tried our best to showcase the machine in just 12 out of 40+ pictures, still have a query? Feel free to ask us for more images

 

  1. 5.        Package includes:

Toshiba Aplio XG IStyle HDD LCD Ultrasound Machine

Toshiba PLT-704AT Linear Array Probe

Toshiba PVT-382BT Convex Ultrasound Probe

      Toshiba PLT-1204AT Linear Array Ultrasound Probe


      Sony UP 897 Digital Printer

      Power Cord    

       

 

  1. Sterilize : No
  2. Manual : No
  3. Cleaned : Yes
  4. Shipping Weight  : 600 lbs                               


Shipping Ready :  No

Stock ID :  16777  

 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED

  1. 1.    Overall Condition:- As seen in images  -   Very Good   
  2. 2.    Physical Condition:  Please review images before bidding -  Very Good
  3. 3.    Working Condition: Tested & Perfectly working refer to the images for functionality..All knobs are working , touch screen small monitor is responsive, LCD has HDD display , Probes are offered in AS IS condition, read the Probe analysis in the short description .....will receive item as pictured ……………(offered AS IS)
  4. 4.    “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  6. 6.    Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.